High performance 3 phase power protection designed for maximum flexibility

The Boxer Series An Advanced UPS Technology

High Performance Power Protection Designed for Maximum Efficiency and Flexibility
Boxer Series is a true Online Double Conversion, new generation fully digital controlled UPS. Its highly flexible design meets high efficiency and high availability power needs of a wide variety of critical applications and delivers an advanced power solution with low cost of ownership.

High Performance Power Protection Designed for Maximum Efficiency and Flexibility

Equipped with its new IGBT rectifier Boxer series keeps your critical loads protected while its space-saving compact design and front access for maintenance successfully reduce mean time to repair (MTTR). Thanks to the wide variety of accessories and options Boxer Series presents maximum flexibility advantage to users and optimizes total
cost of ownership

  • No expensive software needed to commission, service, test, replace batteries, etc…unlike other manufacturers where you never truly own your ups because you are restricted by their tech software
  • True full online double conversion ups topology for completely clean power output
  • Balancing of input current on all phases for optimum metered power
  • Perfect generator compatibility with all relevant brands
  • Comes ready with SNMP network management Card and AS400/dry contact card
  • Comes Parallel ready for up to 16 units together
  • Ultra Basic design allows any ups technician to repair, service, replace batteries etc… very easily
  • Fully DSP controlled
  • 10kva to 120 kva 60% of boards are inter-compatible which can help to reduce any repair time
  • Built in rectifier and inverter protection on Manual bypass switch: incorrect switching protection
  • Large 850VDC Buss Power capacity for faster response to changing load and supply power conditions
  • Advanced intelligent battery management and charging systems to prolong overall battery lifespan
  • 64 and 62 battery config adjustable, to allow for super-fast battery fault resolution onsite
  • IGBT PWM Rectifier and inverter technology
  • All UPS IGBTs, relays, contactors, fans, connectors etc all available from us or any local electrical/electronic wholesaler (very common spares)
  • Incredibly high speed dead short, short circuit, load impact and overload protection built in
  • 500 real time highly detailed event log recording with parameters
  • Full UPS spares availability and technical backup 24/7 across Africa
  • Wide input voltage range, great for areas with bad power supply issues
  • KVA power capacity can be upgraded on UPS on site to allow for future equipment expansion if needed
  • Spare components available inside ups for even faster repairs if ever needed
  • Duel redundant power supply boards for consistent internal workings of ups
  • Adjustable walk in time can be set to ensure load transfer in a desired timeframe

Features:

  • DSP Power Factor Corrected IGBT Rectifier

    IGBT based power factor correction technology provides Input Power Factor close to 1 (≥0.99) and keeps Input Current Total Harmonic
    Distortion (THDi) less than 3%, that helps to avoid the disturbance.

  • Low Input Current THD

    (THDi) less than 3% avoids the disturbance to connected loads

  • Digital Control System

    All of the control functions for Boxer Series UPS including power-on, start-up control, input stage power factor control, battery charging and boosting control, output stage ac voltage regulation and shut-down control, can be realized by using a single DSP control board.

  • High Input Power Factor

    0,99 Input power factor ensures clean and sinusoidal input current. The high input power leads to reduced electricity pay-out, minimizes cable, switchboard, fuse and generator requirements, thus reducing investment cost.

  • High Efficiency & Low Total Cost of Ownership

    With its high efficiency up to 93% Boxer Series UPS consumes less energy to supply the loads. Thanks to this high efficiency rate, the percentage of energy that is produced as heat is reduced to a minimum. As a result of decreased heat emission users can reduce their electricity usage and air conditioning requirements.

  • Static & Manual (Maintenance) Bypass

    Boxer Series includes standard static and manual bypass. Static bypass provides safe failure to mains if the UPS is overloaded or develops a fault condition. Where EMI filters are used to help to neutralize spikes and electrical noise, the load may be routed through bypass to provide further protection. Manual bypass function is intended only for maintenance work, this bypass supply is incorporated into the Boxer UPS design. Manual bypass is used to power down the UPS without interrupting the power to the load. With this feature it is completely safe for the technical personnel to work on the faulty UPS.

  • Flexibility

    Boxer is compatible with wide range of application. Flexibility achieved through many choices, including type of battery, single or multi-unit configuration, accessories and options.

    • Frequency converter mode
    • Optional temperature sensor for external battery cabinets (to assist the recharge voltage compensation)
    • Additional battery chargers to optimize charge time
    • Optional separated bypass
    • Isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output
    • Battery cabinets of different sizes and capacities, for providing extended runtimes.
  • Auto Restart

    When the main and bypass sources fail, the UPS draws power from the battery system to supply the load until the batteries are depleted. When UPS will reach its end of discharge, it will shut down. The UPS will automatically restart and enable output power:

    • After utility power is restored
    • After the “Auto Start Delay Time” is expired (the default delay is 5 minutes)
  • Perfect Generator Compatibility

    Boxer Series is perfectly compatible with diverse sources, especially with generators. When generator power is used, thanks to its robust IGBT rectifier, it ensures clean, uninterrupted power to protected equipment. With high input power factor performance of Boxer Ups series
    it is enough to choose generator with power only %20 higher rated than the UPS. Boxer Series has the ability to adjust power walk-in from 5 to 15 seconds, along with reduced input current distortion.

  • Advanced Battery Management

    Boxer Series guarantees enhanced battery life and maximizes battery performance, life span and reliability through intelligent precision charging. Temperature Compensated Battery Charging monitors performing measurement of external and internal battery temperature and adjusting the charge current rate accordingly. Advanced battery management provides real-time information about battery capacity and back up time, this information can be seen on LCD panel. The Ups tests the batteries at adjustable periods without switching off the system, the test periods can be set by users.

  • EPO(Emergency Power Off)

    EPO function is designed to switch off the UPS in emergency conditions ( fire, flood, etc.). The system will turn off the rectifier, inverter and will stop powering the load immediately (including the inverter and bypass) also the battery stops charging or discharging

  • Reverse Energy Tolerance for Regenerative Loads

    The Boxer UPS can be used with regenerative loads, such as synchronous motors. The regenerative loads pump the energy back to mains, traditional Ups systems burn this feedback
    energy and this causes lower efficiency. Boxer Series Ups with IGBT rectifier are able to absorb intermittent load generated power. Additionally, this reverse power tolerance permits execution of important system operations like closed transition transfers of the UPS load directly to an engine generator source.

  • Advanced User Interface

    Boxer Series UPS has Large and user-friendly 320×240 LCD display that provides operating information in four different languages. Thanks to this advanced LCD display all parameters
    of working device can be monitored and controlled. UPS is capable of recording up to 500 events.

  • Parallel Operation

    Boxer Series features easy and simple scalability and redundancy. It is ready to grow with your business demands. Different power rated units and any number of UPS can be connected in
    parallel. Power Increase: The UPS’s can be connected in parallel to increase total capacity of the system. If one of the devices goes out of order, the critical loads are transferred to by-pass.